6-11 Communications
Special
Commands
CMD
(hex) Name Function
2A Key Press Adds a value to the keyboard buffer; just like pressing a key.
Cmd: ! ADR 2A XX CSM <CR>
Reply: A <CR>
where “XX” is the key number in hex. See “Keypad Diagnostics”
in Section 7 for a method to determine the key number for each
key on the keypad.
2B En Mot Spt Enable “Motion ANDing” programming at operator level.
Put: ! ADR 2B P <00 or 01> CSM <CR>
Reply: A <CR>
Get: ! ADR 2B G CSM <CR>
Reply: A <00 or 01> CSM <CR>
where “00” = disabled, “01” = enabled.
2C En Offset Enable “Offset” programming at operator level.
Put: ! ADR 2C P <00 or 01> CSM <CR>
Reply: A <CR>
Get: ! ADR 2C G CSM <CR>
Reply: A <00 or 01> CSM <CR>
where “00” = disabled, “01” = enabled.
2D En Act Pgm “Active Program” enable at operator level.
Put: ! ADR 2D P <00 or 01> CSM <CR>
Reply: A <CR>
Get: ! ADR 2D G CSM <CR>
Reply: A <00 or 01> CSM <CR>
where “00” = disabled, “01” = enabled.
2E En Spd Cmp Enable “Speed Comp” programming at operator level.
Put: ADR 2E P XX <00 or 01> CSM <CR>
Reply: A <CR>
Get: ! ADR 2E G XX CSM <CR>
Reply: A <00 or 01> CSM <CR>
where “XX” is the channel number minus 1, in hex. “00” =
disabled, “01” = enabled.
2F En Timed Out Enable “Timed Output” programming at operator level.
Put: ! ADR 2F P XX <00 or 01> CSM <CR>
Reply: A <CR>
Get: ! ADR 2F G XX CSM <CR>
Reply: A <00 or 01> CSM <CR>
where “XX” is the channel number minus 1, in hex. “00” =
disabled, “01” = enabled.
Serial Commands (cont’d)