3-20 Programming
Password
Menu Path MAIN SCREEN PASSWORD
This screen provides an area to enter a password. It also shows the current program-
ming access level and the status of the Programming Enable terminals on the back of
the keypad, Figure 12.
Screen
Enable Levels There are three programming access levels; OPERATOR, SETUP, and
MASTER. See Figure 21 for a summary of the programming functions available to the
different levels. The codes that correspond to each level are established in the EN-
ABLE CODES screen.
Entering a Password Enter a password through the numeric keypad followed by ENT. As you press the
number keys, the asterisks will be replaced by dashes. If you make a mistake, press
CLR to erase the last key you pushed.
If you enter a password that has been programmed through ENABLE CODES, the
keypad will function at the corresponding programming level. See ENABLE CODES for
a description of the various levels.
If either of the programming enable terminals on the back of the keypad is active when
a password is entered, the programming level will be whichever is greater.
Output Status (Cont’d)
Selecting Outputs Press the SEL key to change the set of outputs displayed.
Forcing Outputs Forcing outputs allows you to force an output on or off for diagnostic purposes. This
function is not available on earlier software models.
Note: When leaving the Output Status screen, keep in mind that any outputs that have
been forced will return to their originally programmed state.
Programming Press to access Output 1, causing the “0” to blink. Press to turn this output on.
The “0” will change to a “1”. Select other desired outputs by pressing or . If the
output is already on, a “1” will be present instead of a “0”. So, the “1” will change to a “0”
when the output is forced.
Press to return to output number selection. Outputs will remain forced until you
leave the Output Status screen. Press to access Outputs 9-17 on the PS-6144-17
and Outputs 9-16 or 17-25 on the PS-6144-25.
PASSWORD:--**<
LEV:NONE INP:OFF
Dashes replace asterisks as numbers are entered
PASSWORD:****<
LEV:MAS INP:OFF
Dashes change back to asterisks with ENT
Enable level shown if number matches programmed password value
PASSWORD:****<
LEV:NONE INP:OFF
Password entry area
Keypad programming terminal input statu
s
Current programming level (hardware or software)