3-24 Programming
Rate Setup
Menu Path MAIN SCREEN to CONFIG MENU to DISPLAY
RATE SETUP
Purpose The Rate Setup function allows you to configure the RPM display on the Main Screen.
Three parameters can be programmed:
Units—The Main Screen can label the resolver speed as Revolutions Per Minute
(RPM), Bags Per Minute (BPM), Cartons Per Minute (CPM), or Inches Per Minute
(IPM).
Rate—The ratio of actual resolver RPM to displayed RPM. This ratio is a fraction
consisting of a multiplier (MPY) over a divider (DIV).
Decimal Points—The controller divides the Rate by 1, 10, 100, or 1000 to display 0,
1, 2, or 3 decimal places, respectively.
Screen
Following are a few examples of the relationships between multiplier (MPY), divider
(DIV), decimal points (DP), actual resolver speed, and displayed resolver speed:
If And And Then And a Is
MPY DIV DP MPY/DIV Resolver Displayed
Is… Is… Is… Is… Speed Of… As…
1 2 0 .5 100 RPM 50 RPM
1 2 1 .5 100 RPM 5.0 RPM
1 2 2 .5 100 RPM .50 RPM
1 2 3 .5 100 RPM .050 RPM
1 1 0 1.0 100 RPM 100 RPM
1 1 1 1.0 100 RPM 10.0 RPM
1 1 2 1.0 100 RPM 1.00 RPM
1 1 3 1.0 100 RPM .100 RPM
2 1 0 2.0 100 RPM 200 RPM
2 1 1 2.0 100 RPM 20.0 RPM
2 1 2 2.0 100 RPM 2.00 RPM
2 1 3 2.0 100 RPM .200 RPM
Programming Units—Move the cursor to the “Units” field and use SEL to toggle between values.
MPY & DIV—Move the cursor to MPY or DIV and use the numeric keys followed by
ENT to enter a value.
DP—Move the cursor to DP and use SEL to toggle between values.
MPY: 1< DP: 0
DIV: 1 RPM
Units: RPM, BPM, CPM, IPM
Divider: 1 through 63
Number of decimal points displayed: 0, 1, 2, or
3
Multiplier: 0 through 1091